產(chǎn)品與市場(chǎng)
S2130
特點(diǎn)
● 可沖孔加工,鉆孔加工鉆頭使用壽命可延長(cháng)
● 優(yōu)異的電性能
● PTH可靠性與FR-4.0相當
● 不具備UV阻擋功能
應用領(lǐng)域
● 儀器儀表、信息家電、汽車(chē)電子、自動(dòng)控制器、游戲機等
● 對于具有CAF要求的應用,建議客戶(hù)對其可靠性進(jìn)行系統評估。
- 產(chǎn)品性能
- 產(chǎn)品證書(shū)
- 資料下載
Items | Method | Condition | Unit | Typical Value | |
---|---|---|---|---|---|
Tg | IPC-TM-650 2.4.25 | DSC | ℃ | 130 | |
Td | IPC-TM-650 2.4.24.6 | 5% wt. loss | ℃ | — | |
CTE (Z-axis) | IPC-TM-650 2.4.24 | Before Tg | ppm/℃ | 60 | |
After Tg | ppm/℃ | 340 | |||
50-260℃ | % | 5.2 | |||
Thermal Stress | IPC-TM-650 2.4.13.1 | 288℃, solder dip | s | >30 | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ.cm | 2.9 x 108 | |
E-24/125 | MΩ.cm | 8.6 x 106 | |||
Surface Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ | 2.8 x 107 | |
E-24/125 | MΩ | 4.8 x 106 | |||
Arc Resistance | IPC-TM-650 2.5.1 | D-48/50+D-4/23 | s | 115 | |
Dielectric Breakdown | IPC-TM-650 2.5.6 | D-48/50+D-4/23 | kV | >45 | |
Dissipation Constant (Dk) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 4.6 | |
|
|
|
|||
Dissipation Factor (Df) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 0.016 | |
|
|
|
|
||
Peel Strength(1Oz HTE copper foil) | IPC-TM-650 2.4.8 | A | N/mm | — | |
After thermal Stress 288℃,10s | N/mm | 1.9 | |||
125℃ | N/mm | 1.7 | |||
Flexural Strength | LW | IPC-TM-650 2.4.4 | A | MPa | 400 |
CW | IPC-TM-650 2.4.4 | A | MPa | 320 | |
Water Absorption | IPC-TM-650 2.6.2.1 | E-1/105+D-24/23 | % | 0.11 | |
CTI | IEC60112 | A | Rating | PLC 3 | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 | |
E-24/125 | Rating | V-0 |
Remarks:
1. Specification sheet: IPC-4101/12, is for your reference only.
2. All the typical value is based on the 1.6mm specimen.
3. All thetypical values listed above are for your reference only and not intended forspecification. Please contact Shengyi Technology Co., Ltd. for detailedinformation. All rights from this data sheet are reserved by Shengyi TechnologyCo., Ltd.
Explanation:C=Humidity conditioning, D=Immersion conditioning in distilled water,E=Temperature conditioning
Thefirst digit following the letter indicates the duration of preconditioning inhours, the second digit the preconditioning temperature in ℃ andthe third digit the relative humidity.